Central Ground Water Authority (CGWA) guidelines, here are the specifications for Electromagnetic Flow Meters used for groundwater extraction monitoring:
Meter Type: The flow meter should be either an Electromagnetic flow meter or an Ultrasonic meter.
Accuracy: The meter must have an accuracy class of 2 (T50) as per ISO 4064:2014 standards.
Flow Range: The flow range accuracy should be better than ±2%.
Size Options:
DN40: Flow range from 0.5 lps to 5 lps
DN100: Flow range from 3 lps to 30 lps
DN150: Flow range from 13 lps to 130 lps
Power Source: The meter can be either battery operated or powered through a UPS.
Ingress Protection: The meter should comply with IP 68 ingress protection.
Leak and Flow Detection: The meter should be capable of detecting leaks, zero flow, and high flow.
Telemetry System:
The meter should transmit data to a secure cloud.
Transmission frequency: Minimum 2 times per day.

What are the benefits of using electromagnetic flow meters?
How can I ensure proper installation and calibration?
Tell me more about Central Ground Water Authority (CGWA).

Response stopped

Using
relevant sources
Central Ground Water Authority (CGWA) guidelines, here are the specifications for Electromagnetic Flow Meters used for groundwater extraction monitoring:

Meter Type: The flow meter should be either an Electromagnetic flow meter or an Ultrasonic meter.
Accuracy: The meter must have an accuracy class of 2 (T50) as per ISO 4064:2014 standards.
Flow Range: The flow range accuracy should be better than ±2%.
Size Options:
DN40: Flow range from 0.5 lps to 5 lps
DN100: Flow range from 3 lps to 30 lps
DN150: Flow range from 13 lps to 130 lps
Power Source: The meter can be either battery operated or powered through a UPS.
Ingress Protection: The meter should comply with IP 68 ingress protection.
Leak and Flow Detection: The meter should be capable of detecting leaks, zero flow, and high flow.
Telemetry System:
The meter should transmit data to a secure cloud.
Transmission frequency: Minimum 2 times per day.
Battery life: At least 3 years with 2 transmissions per day (replaceable without data loss).
Data transmitted: Real-time data, cumulative forward/reverse flow volume, pump working hours, meter serial number, last calibration date, and borewell ID provided by CGWA.
The telemetry system should have proper mechanical and electronic sealing.