Vadodara
+918690924755

'dth hard strata'

Items tagged with 'dth hard strata'

product image
Rain Water Harvesting System

Water well Drilling Machine, Water well DTH drilling machines & Drilling Rig Machine Water Well Drilling Services water well drilling services throughout India. The company owns 25 water well drill rigs with a capacity to bore 30 meters to 300 meters deploying compressor of 1500 cfm/400 psi. Chiefly utilized for water well drilling, our rig fleet allows customization based on client requirements. Recharge Well Drilling Services. Methods and techniques for ground water recharge. Types of Soil tests for building construction works depend on properties of soil. Design of the foundation is based on soil test report of construction site. Soil tests for construction of buildings or any structure is the first step in construction planning to understand the suitability of soil for proposed construction work. Soil which is responsible for allowing the stresses coming from the structure should be well tested to give excellent performance. If soil shouldn’t tested correctly then the whole building or structure is damaged or collapsed or leaned like leaning tower of Pisa. So, soil inspection or testing is the first step to proceed any construction Allegiance Water Management www.allegianceindia.in Email : info.allegianceentp@gmail.com Contact : 8690924755 ; 9408425896

Send Message
product image
Rain Water Harvesting System

Percolation Pit is also like Rainwater Harvesting System A percolation pit, in its most low-tech form, is a simple hole dug into the ground. It facilitates groundwater recharge through infiltration of surface runoff into the soil or rock. Differences to contour trenches: Better water storage capability due to greater depth. Percolation tank is an artificially created surface water body, submerging in its reservoir a highly permeable land so that surface runoff is made to percolate and recharge the ground water storage. The percolation tanks are mostly earthen dams with masonry structure only for spillway. Percolation tank is an artificially created surface water body, submerging in its reservoir a highly permeable land so that surface runoff is made to percolate and recharge the ground water storage. Percolation tank should be constructed preferable on second to third order streams, located on highly fractured and weathered rocks which have lateral continuity down stream. The recharged area down stream should have sufficient number of wells and cultivable land to benefit from the augmented ground water. The size of percolation tank should be governed by percolation capacity of strata in the tank bed. Normally percolation tanks are designed for storage capacity of 0.1 to 0.5 MCM. It is necessary to design the tank to provide a ponded water column generally between 3 & 4.5 m. The percolation tanks are mostly earthen dams with masonry structure only for spillway. The purpose of the percolation tank is to recharge the ground water storage and hence seepage below the seat of the bed is permissible. for dams upto 4.5 m. height, cut off trenches are not necessary and keying and benching between the dam seat and the natural ground is sufficient.

Send Message
product image
Rainwater collection Pond

Water Conservation, Ground Water Rejuvenation and Development via Rainwater Management and Harvesting Rainwater through Ponds and Borewell Recharging Structures to Support Increasing Demand of Water for Daily usage for Domestic, Industrial and Agricultural purposes. Water Conservation and Harvesting Structures in Naturally Water Scarce Regions creates Geo-Hydrological Opportunity and Economic Viability. Ponds recharging structure, farm pond, stop Dam, and small pond etc. It is seen that different Geographical Location and unique Geophysical and Hydrological Nature and every situation needs to be addressed, separately, the groundwater recharge capacity of the varies regions may vary depending upon area specific geophysical nature of earth strata. Recharge Wells provide an opportunity to extract sub-surface flow of the region without exploiting the Groundwater reserve.

Send Message
product image
Rooftop Rain Water Harvesting Filters

Rooftop Harvesting Filters. FL 200/250 (Rooftop Area upto 2500 Sq.ft.) The characteristic features of FL Series Dual Intensity Rain Water Harvesting Filter is its capacity to take up the load up to 10 to 225 square meters of roof area with variable intensity of rainfall of 5 to 75 mm/hour with a discharge capacity of 10 to 225 liters per minute. This filter can be conveniently used for harvesting rainwater for individual households, schools, apartments, institutions, and commercial buildings of medium sizes. • Item Code: FL-200 Suitable up to area: 225 SQMTRS Max: Intensity of Rainfall: 75 mm/hr Working Principle : Cohesive Force & Centrifugal force Operating Pressure: Less than 2 feet of head (0.060kg/cm2) Capacity: 225 LPM Filter Element: SS-304 Screen Mesh Size: 250 Microns Inlet: 110 MM Clean Water Outlet: 75 MM Drain Outlet: 90 MM Housing: High Density Polyethylene Efficiency of Filter: Above 90% Source of Power: Gravity

Send Message

Still searching for
dth hard strata?