Vadodara
+918690924755

'borewell recharging structures'

Items tagged with 'borewell recharging structures'

product image
Rainwater collection Pond

Water Conservation, Ground Water Rejuvenation and Development via Rainwater Management and Harvesting Rainwater through Ponds and Borewell Recharging Structures to Support Increasing Demand of Water for Daily usage for Domestic, Industrial and Agricultural purposes. Water Conservation and Harvesting Structures in Naturally Water Scarce Regions creates Geo-Hydrological Opportunity and Economic Viability. Ponds recharging structure, farm pond, stop Dam, and small pond etc. It is seen that different Geographical Location and unique Geophysical and Hydrological Nature and every situation needs to be addressed, separately, the groundwater recharge capacity of the varies regions may vary depending upon area specific geophysical nature of earth strata. Recharge Wells provide an opportunity to extract sub-surface flow of the region without exploiting the Groundwater reserve.

Send Message
product image
Rain water Harvesting

"Injection well " New & Innovative Technology for Rainwater Harvesting System Products that are precisely coordinated, scientifically designed all-in-one Rainwater Harvesting solutions and dedicated service. 'Allegiance Water Management ' also undertakes turnkey projects in corporate sector/ industries/ government undertaking etc. and is capable of handling large projects right from Rain Water Harvesting design, supply and installation to providing end- to-end solutions. 'Allegiance' is equipped with a dedicated and experienced team of engineers, technician, workmen along with special installation equipment's, drilling rigs, civil structures etc. Highly trained technical team conducts the Rainwater Harvesting technical survey by studying the layout of the site and building. Existing piping system of rainwater and storm drains are studied. Gradient and landscape of the site and building are obtained. Designing and installation of innovative customized system is done with precise scientific approach. These solutions include: diverting existing rainwater pipes, deployment of underground storage, auto pumping system, piping, filtering, storage, utilization etc. Designing and construction of ground water recharging structures. Complete solutions for water neutrality establishment projects.

Send Message
product image
Rain water Harvesting Filters

"Rainy" Rainwater Harvesting Filters Completely Indigenous and Patented Technology for Dual Intensity Rainwater Harvesting Filters called 'Rainy'. For groundwater recharging, our innovation uses an injection well equipped with "V-Wire Screens" that enables replenishment of groundwater source. Rainwater is one of the purest source of water with less then 50mg/ litre of Total Dissolved Solids (TDS). Minimalistic, easy-to-install and easy to maintain Products. Reduction of Carbon Footprint and Recharge water source to avail clean water for consumption. Working Principle: When the rainwater along with dirt & debris flows by gravity through the downtake pipes, it enters into the filter and starts rotating in anticlockwise direction at the periphery of the upper housing, this enables it to flow into the SS-304 filter element placed in the lower housing in angular motion at specific speed & velocity, which creates cohesive force at low intensity & centrifugal force at high intensity of rainfall. In both situations, involving low & high intensity of rainfall, the working principle of the filter based on cohesive & centrifugal force respectively, aids the filter element to flush out dirt & debris automatically. The water then passes through the drain outlet and simultaneously diverts clean water into the sump/ recharging well through the clean water outlet, which can be used for reutilization or recharging of groundwater source. Special Features : What makes 'Rainy' unique? Dual Intensity Filters works on the principle of Cohesive & Centrifugal force. The open drain design does not allow stagnation of water and dirt particles. Works on Gravitation force (No external energy required). Cost effective and affordable. Compact in size and wall mounted. Inbuilt self-cleaning mechanism. Automatic flush out of dirt and debris. No consumables required. Flexibility in pipe connection to any angle. Tough UV stabilized high density polyethylene housing. Filter Element SS-304 Multi-Surface Screen food grade. All the material used are food grade and recyclable. Filter Pipe connections can be turned up to 360 Degrees allowing it to suit the given site conditions. Simple in connection, which any local plumber can easily install. The filter efficiency remains unchanged even with the variation of intensity of rainfall. The filters do not have any moving parts; there is no wear & tear of the filter allowing for long life span. Technology works on the Gravitational Principle so saves power (reduces the pumping of water from distant places & depths). Swirling movement of water is formed while ‘Rainy’ filters are under operation, this leads to aeration of water. Thus, increases the water quality. Dual Intensity Filters works on the principle of Cohesive & Centrifugal force. The open drain design does not allow stagnation of water and dirt particles. Works on Gravitation force (No external energy required). Cost effective and affordable. Compact in size and wall mounted. Inbuilt self-cleaning mechanism. Automatic flush out of dirt and debris. No consumables required. Flexibility in pipe connection to any angle. Tough UV stabilized high density polyethylene housing. Filter Element SS-304 Multi-Surface Screen food grade. All the material used are food grade and recyclable. Filter Pipe connections can be turned up to 360 Degrees allowing it to suit the given site conditions. Simple in connection, which any local plumber can easily install. The filter efficiency remains unchanged even with the variation of intensity of rainfall. The filters do not have any moving parts; there is no wear & tear of the filter allowing for long life span. Technology works on the Gravitational Principle so saves power (reduces the pumping of water from distant places & depths). Swirling movement of water is formed while ‘Rainy’ filters are under operation, this leads to aeration of water. Thus, increases the water quality.

Send Message
product image
Borewell Drilling Services

Water well Drilling Machine, Water well DTH drilling machines & Drilling Rig Machine Water Well Drilling Services water well drilling services throughout India. The company owns 25 water well drill rigs with a capacity to bore 30 meters to 300 meters deploying compressor of 1500 cfm/400 psi. Chiefly utilized for water well drilling, our rig fleet allows customization based on client requirements. Recharge Well Drilling Services. Methods and techniques for ground water recharge. Types of Soil tests for building construction works depend on properties of soil. Design of the foundation is based on soil test report of construction site. Soil tests for construction of buildings or any structure is the first step in construction planning to understand the suitability of soil for proposed construction work. Soil which is responsible for allowing the stresses coming from the structure should be well tested to give excellent performance. If soil shouldn’t tested correctly then the whole building or structure is damaged or collapsed or leaned like leaning tower of Pisa. So, soil inspection or testing is the first step to proceed any construction Allegiance Water Management www.allegianceindia.in Email : info.allegianceentp@gmail.com Contact : 8690924755 ; 9408425896

Send Message
product image
Water Flow Meter

Digital water flow meter as per CGWA Compliance ELECTROMAGNETIC FLOW METER Digital Flow Meter With Telemetry As Per CGWA Guidelines Installation of Digital Water Flow Meter on Ground water abstraction structures Whereas the Central Government constituted the Central Ground Water Authority (hereinafter referred to as the Authority) vide notification Number S.O. 38(E), dated 14th January, 1997, followed by notification number S.O. 1124(E) dated 6th November, 2000 and S.O. 1121 (E) dated 13th May, 2010 of the Government of India in the Ministry of Environment & Forests, for the purposes of regulation and control of ground water development and management in the whole of India and to issue necessary regulatory directions. And whereas the Authority has issued ‘Guidelines to control and regulate ground water extraction in India’ vide notification number 3289(E) dated 24th September, 2020, wherein under Section 9 (i) “Installation of digital water flow meter (conforming to BIS/ IS standards) having telemetry system in the abstraction structure(s) shall be mandatory for all users seeking No Objection Certificate and intimation regarding their installation shall be communicated to the CGWA within 30 days of grant of No Objection Certificate through the web-portal.” THIS IS TO BRING TO THE NOTICE OF ALL GROUND WATER USERS THAT: All the project proponents/users drawing ground water and seeking/having NOC shall have to mandatorily install tamper-proof digital water flow meters with telemetry on all the ground water abstraction structures within their premises. All the Micro and Small Enterprises drawing less than 10 cum/day shall also be mandatorily required to install digital water flow meters on all the ground water abstraction structures within their premises. Such enterprises shall be subjected to randomised inspections. The afore-mentioned conditions need to be strictly followed by all the users and any ground water withdrawal without the installation of tamper-proof digital water flow meters and telemetry (wherever applicable) shall be construed as illegal. Non-compliance of these conditions shall invite a Penalty provision and/or Environmental Compensation against the proponent for illegal withdrawal of ground water as per the CGWA Guidelines and may result in cancellation/rejection of NOC and sealing of ground water abstraction structures.

Send Message
product image
Geophysical survey for Rainwater Harvesting

Geophysical survey for Rainwater Harvesting, a number of years of experience and technical knowledge we are able to provide you the most suitable locations to drill a Borewell on your site. By using technically advanced equipment like Resistivity meters & Electromagnetic (EM) VLF instruments we provide high quality service with excellent execution. Before any Rainwater Harvesting System construction is done, we help you in identifying the nature of Soil Structure & what is the actual Depth to recharge Rainwater.

Send Message
product image
Rooftop Rainwater Harvesting Filters

Rooftop Harvesting Filters. FL 200/250 (Rooftop Area upto 2500 Sq.ft.) The characteristic features of FL Series Dual Intensity Rain Water Harvesting Filter is its capacity to take up the load up to 10 to 225 square meters of roof area with variable intensity of rainfall of 5 to 75 mm/hour with a discharge capacity of 10 to 225 liters per minute. This filter can be conveniently used for harvesting rainwater for individual households, schools, apartments, institutions, and commercial buildings of medium sizes. • Item Code: FL-200 Suitable up to area: 225 SQMTRS Max: Intensity of Rainfall: 75 mm/hr Working Principle : Cohesive Force & Centrifugal force Operating Pressure: Less than 2 feet of head (0.060kg/cm2) Capacity: 225 LPM Filter Element: SS-304 Screen Mesh Size: 250 Microns Inlet: 110 MM Clean Water Outlet: 75 MM Drain Outlet: 90 MM Housing: High Density Polyethylene Efficiency of Filter: Above 90% Source of Power: Gravity

Send Message

Still searching for
borewell recharging structures?