Vadodara
+918690924755

'a shallow aquifer b deeper aquifer'

Items tagged with 'a shallow aquifer b deeper aquifer'

product image
CGWBNOC

CGWA Clearance Central Ground Water Board (CGWB) . Statement indicating position of pending cases received for NOC for ground water withdrawal. Statement showing list of project proposals to whom NOC for ground water withdrawal has been issued. The annual replenishable ground water resources availability plays an important role in defining the guidelines. The latest assessment of the state wise ground water resources as on 31.03.2009 is available at the Central Ground Water Board . As per the ground water resource estimates of 2009, out of the 5842 assessment units (Blocks, Mandals, Talukas, districts), 802 over-exploited units, 169 critical units, 523 semi-critical units, 4277 safe units and 71 saline units have been identified across the country by Central Ground Water Board. The Annual replenishable ground water resources have been estimated as 431 Billion Cubic Meters (bcm). The Net Ground Water Availability is 396 bcm and the overall stage of ground water development of the country is 61%. Therefore, prior permission/NOC from CGWA has to be obtained before construction of any Groundwater abstraction structure viz. Tube wells, Bore wells, Dug wells etc. Allegiance can offers its client the following services: Examining the area of the groundwater against availability Water requirement Availability of aquifer A Shallow aquifer B Deeper aquifer Status of the groundwater development of the area Preparation of proposal for augmentation of groundwater abstraction Preparation and implementation of water conservation measures Facilitation for obtaining NOC from CGWA, New Delhi

Send Message
product image
Rainwater Harvesting System

Percolation Pit It is a shallow excavated trench filled with gravel or crushed stone that is designed to infiltrate stormwater though permeable soils into the groundwater aquifer. A percolation trench is similar to a dry well, which is typically an excavated hole filled with gravel. we are engaged to offer the best Percolating Well Service. The provided service is executed using the progressive techniques under the supervision of our brilliant professionals. Offered service is highly demanded among our clients, owing to their various associated features like promptness and on time execution.

Send Message
product image
Percolation well

It is a shallow excavated trench filled with gravel or crushed stone that is designed to infiltrate stormwater though permeable soils into the groundwater aquifer. A percolation trench is similar to a dry well, which is typically an excavated hole filled with gravel. we are engaged to offer the best Percolating Well Service. The provided service is executed using the progressive techniques under the supervision of our brilliant professionals. Offered service is highly demanded among our clients, owing to their various associated features like promptness and on time execution.

Send Message
product image
V Wire screen

The all-welded wedge wire screens are made from two elements the V-shaped wedge wire is helically wound around an array of internal longitudinal support rods. Each intersection of wire and rods is automatically resistance welded, creating a very strong cage-like cylinder with one continuous slot spiraling along its full length. The gap between the wires, also called slot or aperture, is manufactured to customer specification, allows water to flow from the surrounding aquifer into the screen, The slots can be very narrow to keep out fine sand grains, which could otherwise damage your pump through abrasion. NON PLUGGING SLOTS V-shaped wire creating, two point particle contact preventing plugging. Inwardly opening slots (in-flow) preventing sand particles from remaining lodged in screen. The V-shaped wire enhances well efficiency, ensures consistent pumping and long well life. LARGE OPEN AREA The continuous slot wedge wire offers higher open area than any other type of screens used for water well applications, such as slotted pipe, punched pipe, louver screens. Wedge wires for each application are selected to maximize open area, resulting in the lowest possible cost for water extraction. TECHNICAL DETAILS Available sizes from 1" (25 mm) to 22" (560 mm) Water well screens designed to suit well depth Available in slots sizes from 0.15 mm to 3 mm Length up to 6 metres available Materials: LCG (Low Carbon Galvanised) / SS304 / S316L / SS316 / SS316L - or as required to meet Customer requirements. End fittings - to suit Customer requirements

Send Message
product image
Borewell Drilling Services

Water well Drilling Machine, Water well DTH drilling machines & Drilling Rig Machine Water Well Drilling Services water well drilling services throughout India. The company owns 25 water well drill rigs with a capacity to bore 30 meters to 300 meters deploying compressor of 1500 cfm/400 psi. Chiefly utilized for water well drilling, our rig fleet allows customization based on client requirements. Recharge Well Drilling Services. Methods and techniques for ground water recharge. Types of Soil tests for building construction works depend on properties of soil. Design of the foundation is based on soil test report of construction site. Soil tests for construction of buildings or any structure is the first step in construction planning to understand the suitability of soil for proposed construction work. Soil which is responsible for allowing the stresses coming from the structure should be well tested to give excellent performance. If soil shouldn’t tested correctly then the whole building or structure is damaged or collapsed or leaned like leaning tower of Pisa. So, soil inspection or testing is the first step to proceed any construction Allegiance Water Management www.allegianceindia.in Email : info.allegianceentp@gmail.com Contact : 8690924755 ; 9408425896

Send Message
product image
Rainwater Harvesting

Roof Top Rain Water Harvesting What is Roof Top Rain Water Harvesting? Rooftop Rain Water Harvesting is the technique through which rain water is captured from the roof catchments and stored in reservoirs. Harvested rain water can be stored in sub-surface ground water reservoir by adopting artificial recharge techniques to meet the household needs through storage in tanks. The Main Objective of rooftop rain water harvesting is to make water available for future use. Capturing and storing rain water for use is particularly important in dryland, hilly, urban and coastal areas. In alluvial areas energy saving for 1m. rise in ground water level is around 0.40 kilo watt per hour. Need for Rooftop Rain Water Harvesting 1. To meet the ever increasing demand for water 2. To reduce the runoff which chokes storm drains 3. To avoid flooding of roads 4. To augment the ground water storage and control decline of water levels 5. To reduce ground water pollution 6. To improve the quality of ground water 7. To reduce the soil erosion 8. To supplement domestic water requirement during summer, drought etc. Advantages of Rain Water Harvesting 1. Provides self-sufficiency to your water supply 2. Reduces the cost for pumping of ground water 3. Provides high quality water, soft and low in minerals 4. Improves the quality of ground water through dilution when recharged to ground water 5. Reduces soil erosion in urban areas 6. The rooftop rain water harvesting is less expensive 7. Rainwater harvesting systems are simple which can be adopted by individuals 8. Rooftop rain water harvesting systems are easy to construct, operate and maintain 9. In hilly terrains, rain water harvesting is preferred 10. In saline or coastal areas, rain water provides good quality water and when recharged to ground water, it reduces salinity and also helps in maintaining balance between the fresh-saline water interface 11. In Islands, due to limited extent of fresh water aquifers, rain water harvesting is the most preferred source of water for domestic use 12. In desert, where rain fall is low, rain water harvesting has been providing relief to people

Send Message
product image
Rooftop Rainwater Harvesting Filters

Rooftop Harvesting Filters. FL 200/250 (Rooftop Area upto 2500 Sq.ft.) The characteristic features of FL Series Dual Intensity Rain Water Harvesting Filter is its capacity to take up the load up to 10 to 225 square meters of roof area with variable intensity of rainfall of 5 to 75 mm/hour with a discharge capacity of 10 to 225 liters per minute. This filter can be conveniently used for harvesting rainwater for individual households, schools, apartments, institutions, and commercial buildings of medium sizes. • Item Code: FL-200 Suitable up to area: 225 SQMTRS Max: Intensity of Rainfall: 75 mm/hr Working Principle : Cohesive Force & Centrifugal force Operating Pressure: Less than 2 feet of head (0.060kg/cm2) Capacity: 225 LPM Filter Element: SS-304 Screen Mesh Size: 250 Microns Inlet: 110 MM Clean Water Outlet: 75 MM Drain Outlet: 90 MM Housing: High Density Polyethylene Efficiency of Filter: Above 90% Source of Power: Gravity

Send Message

Still searching for
a shallow aquifer b deeper aquifer?