Surat
+918690924755

'construction of buildings'

Items tagged with 'construction of buildings'

product image
Water Flow Meter

The Woltman Type Flow Meter by Allegiance India™ is a high-precision, heavy-duty water meter designed for large-scale water consumption measurement. Ideal for industrial, commercial, and municipal applications, this meter features a horizontal turbine (Woltman) mechanism that ensures accurate and efficient water flow monitoring even under high-pressure conditions. Key Features: ✅ Woltman Type with Horizontal Turbine – Ensures high accuracy and durability ✅ Flanged End Connection – Easy installation in pipelines ✅ Magnetic Transmission – Reduces wear and increases operational lifespan ✅ ISO 4064 Certified – Complies with global accuracy and quality standards ✅ Low-Pressure Drop – Efficient water flow measurement with minimal resistance ✅ Corrosion-Resistant Body – Durable construction for long service life ✅ Available in Multiple Sizes – Ranges from 50mm to 600mm Applications: 🏭 Industrial Water Supply – Manufacturing plants, chemical industries 🏢 Commercial & Municipal Water Distribution – Smart city projects, large buildings 🚰 Irrigation Systems – Efficient water management for agriculture 💧 Water Treatment Plants – Accurate monitoring of treated water supply

Send Message
product image
Rooftop Rain Water Harvesting Filters

Rainy Rainwater Harvesting Filter. FL 300 (Rooftop Area upto 3600 sq.ft) The characteristic features of FL Series Dual Intensity Rain Water Harvesting Filter is its capacity to take up the load up to 10 to 350 square meters of roof area with variable intensity of rainfall of 5 to 75 mm/hour with a discharge capacity of 10 to 340 liters per minute. This filter can be conveniently used for harvesting rainwater for individual households, schools, apartments, institutions, hospitals and commercial buildings of medium and small sizes. • Item Code: FL-300 Suitable up to area: 350 SQMTRS Max: Intensity of Rainfall: 75 mm/hr Working Principle : Cohesive Force & Centrifugal force Operating Pressure: Less than 2 feet of head (0.060kg/cm2) Capacity: 340 LPM Filter Element: SS-304 Screen Mesh Size: 250 Microns Inlet: 110 MM Clean Water Outlet: 90 MM Drain Outlet: 90 MM Housing: High Density Polyethylene Efficiency of Filter: Above 90% Source of Power: Gravity

Send Message
product image
Rain Water Harvesting System

Geophysical survey for Rainwater Harvesting, a number of years of experience and technical knowledge we are able to provide you the most suitable locations to drill a Borewell on your site. By using technically advanced equipment like Resistivity meters & Electromagnetic (EM) VLF instruments we provide high quality service with excellent execution. Before any Rainwater Harvesting System construction is done, we help you in identifying the nature of Soil Structure & what is the actual Depth to recharge Rainwater.

Send Message
product image
Rain Water Harvesting System

Roof Top Rain Water Harvesting What is Roof Top Rain Water Harvesting? Rooftop Rain Water Harvesting is the technique through which rain water is captured from the roof catchments and stored in reservoirs. Harvested rain water can be stored in sub-surface ground water reservoir by adopting artificial recharge techniques to meet the household needs through storage in tanks. The Main Objective of rooftop rain water harvesting is to make water available for future use. Capturing and storing rain water for use is particularly important in dryland, hilly, urban and coastal areas. In alluvial areas energy saving for 1m. rise in ground water level is around 0.40 kilo watt per hour. Need for Rooftop Rain Water Harvesting 1. To meet the ever increasing demand for water 2. To reduce the runoff which chokes storm drains 3. To avoid flooding of roads 4. To augment the ground water storage and control decline of water levels 5. To reduce ground water pollution 6. To improve the quality of ground water 7. To reduce the soil erosion 8. To supplement domestic water requirement during summer, drought etc. Advantages of Rain Water Harvesting 1. Provides self-sufficiency to your water supply 2. Reduces the cost for pumping of ground water 3. Provides high quality water, soft and low in minerals 4. Improves the quality of ground water through dilution when recharged to ground water 5. Reduces soil erosion in urban areas 6. The rooftop rain water harvesting is less expensive 7. Rainwater harvesting systems are simple which can be adopted by individuals 8. Rooftop rain water harvesting systems are easy to construct, operate and maintain 9. In hilly terrains, rain water harvesting is preferred 10. In saline or coastal areas, rain water provides good quality water and when recharged to ground water, it reduces salinity and also helps in maintaining balance between the fresh-saline water interface 11. In Islands, due to limited extent of fresh water aquifers, rain water harvesting is the most preferred source of water for domestic use 12. In desert, where rain fall is low, rain water harvesting has been providing relief to people

Send Message
product image
CGWA NOC Permission Service

CGWA Clearance Central Ground Water Board (CGWB) . Statement indicating position of pending cases received for NOC for ground water withdrawal. Statement showing list of project proposals to whom NOC for ground water withdrawal has been issued. The annual replenishable ground water resources availability plays an important role in defining the guidelines. The latest assessment of the state wise ground water resources as on 31.03.2009 is available at the Central Ground Water Board . As per the ground water resource estimates of 2009, out of the 5842 assessment units (Blocks, Mandals, Talukas, districts), 802 over-exploited units, 169 critical units, 523 semi-critical units, 4277 safe units and 71 saline units have been identified across the country by Central Ground Water Board. The Annual replenishable ground water resources have been estimated as 431 Billion Cubic Meters (bcm). The Net Ground Water Availability is 396 bcm and the overall stage of ground water development of the country is 61%. Therefore, prior permission/NOC from CGWA has to be obtained before construction of any Groundwater abstraction structure viz. Tube wells, Bore wells, Dug wells etc. Allegiance can offers its client the following services: Examining the area of the groundwater against availability Water requirement Availability of aquifer A Shallow aquifer B Deeper aquifer Status of the groundwater development of the area Preparation of proposal for augmentation of groundwater abstraction Preparation and implementation of water conservation measures Facilitation for obtaining NOC from CGWA, New Delhi

Send Message
product image
V Wire screen

V -WIRE FILTER SCREEN V-Wire Filter Screen/ Rainwater Filters are the best Rainwater Harvesting Filters which are used for Filtration purpose. These filters have Continuous slots, which are Non Choking & Non Clogging and makes Filtration process smooth. There is no wastage of rain water after using this RWH filter. V -WIRE SCREENS is a Proven Product of Proven Technology Trusted Widely for RAINWATER HARVESTING. we are proud to Offer one of the Most Modern Filtration Systems for Rainwater Harvesting (Absolutely Zero Maintenance Cost) with the sole aim of increasing awareness about the Long Term benefits of Rainwater Harvesting using Filter Screens instead of the Conventional Method normally adopted. V-Wire Screen Filter“/ Rainwater Harvesting Filter Screen is a Highly Acceptable Modern Technology in Rain Water Harvesting. It eliminates conventional filtration system, SAVES -Precious Space, Construction Cost and Construction Time for Filtration Tank. Scientific Design helps Cleaning Very Easy and SAVES Maintenance Cost.

Send Message
product image
Rooftop Rain Water Harvesting Filters

Rainwater Harvesting Filters. FL 100 (Rooftop Area upto 1200 Sq. Ft) The characteristic features of FL Series Dual Intensity RWH Filter is its capacity to take up the load up to 10 to 110 square meters of Roof area with variable intensity of rainfall of 5 to 75 mm/ hour with a discharge capacity of 10 to 105 Liters per minute. This filter can be conveniently used for Harvesting Rainwater for Individual households, Schools, and Smaller Roof area Buildings. • Item Code: FL-100 Suitable up to area: 110 SQMTRS Max: Intensity of Rainfall: 75 mm/hr Working Principle : Cohesive Force & Centrifugal force Operating Pressure: Less than 2 feet of head (0.060kg/cm2) Capacity: 105 LPM Filter Element: SS-304 Screen Mesh Size: 250 Microns Inlet: 90 MM Clean Water Outlet: 63 MM Drain Outlet: 90 MM Housing: High Density Polyethylene Efficiency of Filter: Above 90% Source of Power: Gravity

Send Message
product image
Rooftop Rain Water Harvesting Filters

Rooftop Harvesting Filters. FL 200/250 (Rooftop Area upto 2500 Sq.ft.) The characteristic features of FL Series Dual Intensity Rain Water Harvesting Filter is its capacity to take up the load up to 10 to 225 square meters of roof area with variable intensity of rainfall of 5 to 75 mm/hour with a discharge capacity of 10 to 225 liters per minute. This filter can be conveniently used for harvesting rainwater for individual households, schools, apartments, institutions, and commercial buildings of medium sizes. • Item Code: FL-200 Suitable up to area: 225 SQMTRS Max: Intensity of Rainfall: 75 mm/hr Working Principle : Cohesive Force & Centrifugal force Operating Pressure: Less than 2 feet of head (0.060kg/cm2) Capacity: 225 LPM Filter Element: SS-304 Screen Mesh Size: 250 Microns Inlet: 110 MM Clean Water Outlet: 75 MM Drain Outlet: 90 MM Housing: High Density Polyethylene Efficiency of Filter: Above 90% Source of Power: Gravity

Send Message
product image
Rooftop Rain Water Harvesting Filters

Rooftop Rainwater Harvesting Filters. for Industries Use FL 500 (Rooftop Area 5000 Sq.ft.) The characteristic features of FL Series Dual Intensity Rain Water Harvesting Filter is its capacity to take up the load up to 10 to 500 square meters of roof area with variable intensity of rainfall of 5 to 75 mm/hour with a discharge capacity of 10 to 480 liters per minute. This filter can be conveniently used for harvesting rainwater for apartments, institutions, hospitals, commercial buildings, industries, corporate houses of medium and large sizes. • Item Code: FL-500 Suitable up to area: 500 SQMTRS Max: Intensity of Rainfall: 75 mm/hr Working Principle : Cohesive Force & Centrifugal force Operating Pressure: Less than 2 feet of head (0.060kg/cm2) Capacity: 480 LPM Filter Element: SS-304 Screen Mesh Size: 250 Microns Inlet: 110 MM Clean Water Outlet: 90 MM Drain Outlet: 110 MM Housing: High Density Polyethylene Efficiency of Filter: Above 90% Source of Power: Gravity

Send Message

Still searching for
construction of buildings?