Ahmedabad
+919408425896

'1 feet'

Items tagged with '1 feet'

product image
Rooftop Rain Water Harvesting Filters

Rainy Rainwater Harvesting Filter. FL 300 (Rooftop Area upto 3600 sq.ft) The characteristic features of FL Series Dual Intensity Rain Water Harvesting Filter is its capacity to take up the load up to 10 to 350 square meters of roof area with variable intensity of rainfall of 5 to 75 mm/hour with a discharge capacity of 10 to 340 liters per minute. This filter can be conveniently used for harvesting rainwater for individual households, schools, apartments, institutions, hospitals and commercial buildings of medium and small sizes. • Item Code: FL-300 Suitable up to area: 350 SQMTRS Max: Intensity of Rainfall: 75 mm/hr Working Principle : Cohesive Force & Centrifugal force Operating Pressure: Less than 2 feet of head (0.060kg/cm2) Capacity: 340 LPM Filter Element: SS-304 Screen Mesh Size: 250 Microns Inlet: 110 MM Clean Water Outlet: 90 MM Drain Outlet: 90 MM Housing: High Density Polyethylene Efficiency of Filter: Above 90% Source of Power: Gravity

Send Message
product image
Water Flow Meter

Vortex Flow Meter – High-Precision Flow Measurement for Steam, Gas & Liquids Buy Vortex Flow Meter Online | Industrial Flow Monitoring The Vortex Flow Meter is a high-accuracy, maintenance-free flow measurement device designed for steam, gas, air, and liquid applications. Using advanced vortex shedding technology, it ensures precise, stable, and reliable flow measurement with no moving parts, reducing wear and maintenance costs. Why Choose This Vortex Flow Meter? ✅ No Moving Parts – Ensures long-lasting performance with minimal maintenance. ✅ High-Accuracy & Stability – Digital signal processing provides precise flow readings. ✅ Wide Application Compatibility – Suitable for steam, gases, air, and liquids. ✅ Real-Time LCD Display – Monitors instantaneous & totalized flow, temperature, and pressure. ✅ Smart Output & Connectivity – Features 4-20mA output and pulse signal for seamless integration. ✅ Temperature & Pressure Compensation – Ideal for industrial steam and gas flow measurement. Vortex Flow Meter Specifications 📌 Power Supply: 12-32V DC 📌 Output Signal: 4-20mA (Standard), Pulse Output 📌 Process Temperature: Up to 250°C (For higher temperatures, consult factory) 📌 Alarm System: Low alarm (3.8mA) & high alarm (22.0mA) 📌 K-Factor Correction: 2 to 5 Points calibration 📌 Display: Multi-line LCD with real-time monitoring 📌 Compensation: Pressure & temperature compensation for steam and gas applications 📌 Application Scope: Industrial Steam, Gas, Air, and Liquid Flow Measurement Industries & Applications 🔹 Power Plants & Boilers – Steam flow measurement for energy efficiency. 🔹 Oil & Gas Industry – Monitoring gas flow with real-time compensation. 🔹 HVAC & Compressed Air Systems – Ensures accurate airflow control. 🔹 Chemical & Pharmaceutical Processing – Precise liquid and gas measurement. Why Choose This Flow Meter? 🔹 ISO & CE Certified Quality 🔹 High-Precision Flow Monitoring with Digital Control 🔹 Best Prices for Industrial Flow Meters 💡 Upgrade to the Vortex Flow Meter for precise & efficient flow measurement! 📞 Contact Us for Orders & Bulk Pricing

Send Message
product image
Water Flow Meter

Turbine Flow Meter – High-Precision Digital Flow Measurement Buy Turbine Flow Meter Online | Industrial Flow Meters for Liquid Measurement Looking for a high-precision turbine flow meter for liquid flow measurement? Our industrial-grade Turbine Flow Meter is designed for accurate and reliable measurement in water management, oil & gas, chemical processing, and other industrial applications. Why Choose Our Turbine Flow Meter? ✅ High Accuracy & Efficiency – Provides precise flow readings with an accuracy of ±0.5%. ✅ Durable Stainless Steel Body – Corrosion-resistant construction for long-term use. ✅ Wide Flow Range Compatibility – Suitable for various industrial applications. ✅ Multiple Output Options – Pulse, 4-20mA, and MODBUS for seamless data integration. ✅ Low Pressure Drop – Ensures minimal impact on system performance. ✅ Easy Installation & Low Maintenance – Compact and user-friendly design. Turbine Flow Meter Specifications 📌 Measurement Principle: Turbine-based flow sensing 📌 Flow Rate Range: Varies by model 📌 Accuracy: ±0.5% 📌 Output Signal: Pulse, 4-20mA, MODBUS (optional) 📌 Material: Stainless Steel / Aluminum Alloy 📌 Power Supply: 12-24V DC 📌 Temperature Range: -20°C to 120°C 📌 Pressure Rating: Up to 40 Bar Industries & Applications 🔹 Water Management & Treatment – Ideal for monitoring water flow in residential, commercial, and industrial sectors. 🔹 Oil & Gas Industry – Measures fuel, diesel, and petroleum with high accuracy. 🔹 Chemical & Pharmaceutical Processing – Ensures precise flow control for critical applications. 🔹 Food & Beverage Industry – Used for hygienic liquid flow measurement. Why Buy from Allegiance India™? 🔹 Best Prices on Turbine Flow Meters – Get competitive rates on high-quality flow meters. 🔹 Reliable & Certified Products – Trusted by industries for precision and durability. 🔹 Custom Solutions Available – Get the right flow meter tailored to your needs. 💡 Order your Turbine Flow Meter today! Contact us for bulk orders and special pricing. 📞 Get in Touch: Call us or visit our website for more details!

Send Message
product image
Rainwater Harvesting System

Percolation Pit is also like Rainwater Harvesting System A percolation pit, in its most low-tech form, is a simple hole dug into the ground. It facilitates groundwater recharge through infiltration of surface runoff into the soil or rock. Differences to contour trenches: Better water storage capability due to greater depth. Percolation tank is an artificially created surface water body, submerging in its reservoir a highly permeable land so that surface runoff is made to percolate and recharge the ground water storage. The percolation tanks are mostly earthen dams with masonry structure only for spillway. Percolation tank is an artificially created surface water body, submerging in its reservoir a highly permeable land so that surface runoff is made to percolate and recharge the ground water storage. Percolation tank should be constructed preferable on second to third order streams, located on highly fractured and weathered rocks which have lateral continuity down stream. The recharged area down stream should have sufficient number of wells and cultivable land to benefit from the augmented ground water. The size of percolation tank should be governed by percolation capacity of strata in the tank bed. Normally percolation tanks are designed for storage capacity of 0.1 to 0.5 MCM. It is necessary to design the tank to provide a ponded water column generally between 3 & 4.5 m. The percolation tanks are mostly earthen dams with masonry structure only for spillway. The purpose of the percolation tank is to recharge the ground water storage and hence seepage below the seat of the bed is permissible. for dams upto 4.5 m. height, cut off trenches are not necessary and keying and benching between the dam seat and the natural ground is sufficient.

Send Message
product image
Rainwater Harvesting System

Percolation Pit is also like Rainwater Harvesting System A percolation pit, in its most low-tech form, is a simple hole dug into the ground. It facilitates groundwater recharge through infiltration of surface runoff into the soil or rock. Differences to contour trenches: Better water storage capability due to greater depth. Percolation tank is an artificially created surface water body, submerging in its reservoir a highly permeable land so that surface runoff is made to percolate and recharge the ground water storage. The percolation tanks are mostly earthen dams with masonry structure only for spillway. Percolation tank is an artificially created surface water body, submerging in its reservoir a highly permeable land so that surface runoff is made to percolate and recharge the ground water storage. Percolation tank should be constructed preferable on second to third order streams, located on highly fractured and weathered rocks which have lateral continuity down stream. The recharged area down stream should have sufficient number of wells and cultivable land to benefit from the augmented ground water. The size of percolation tank should be governed by percolation capacity of strata in the tank bed. Normally percolation tanks are designed for storage capacity of 0.1 to 0.5 MCM. It is necessary to design the tank to provide a ponded water column generally between 3 & 4.5 m. The percolation tanks are mostly earthen dams with masonry structure only for spillway. The purpose of the percolation tank is to recharge the ground water storage and hence seepage below the seat of the bed is permissible. for dams upto 4.5 m. height, cut off trenches are not necessary and keying and benching between the dam seat and the natural ground is sufficient.

Send Message

Still searching for
1 feet?